CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass Dca

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.6 mm ∅
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSOH Orange RAL 2003











Description
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compact cable design.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
High-end data cable for data centres.
Developed particularly for 40 GBase-T transmission with maximum channel length of 30 metres in End of Row or Top of Rack (EoR / ToR) applications in data centres.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to 2000 MHz.
Applicable for Power over Ethernet (PoE / PoE+).
Developed particularly for 40 GBase-T transmission with maximum channel length of 30 metres in End of Row or Top of Rack (EoR / ToR) applications in data centres.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to 2000 MHz.
Applicable for Power over Ethernet (PoE / PoE+).

Category | 5e | 6 | 6A | 7 | CATV | 7A | 8.2 | ||||
Frequency [MHz] | 1 | 4 | 10 | 100 | 250 | 500 | 600 | 862 | 1000 | 1600 | 2000 |
Attenuation [dB/30m] | 0.54 | 0.95 | 1.5 | 5.0 | 8.0 | 11.3 | 12.5 | 15.6 | 16.3 | 21.0 | 23.5 |
NEXT [dB] | 103 | 103 | 103 | 103 | 97 | 95 | 94 | 92 | 90 | 85 | 80 |
PS NEXT [dB] | 100 | 100 | 100 | 100 | 94 | 92 | 91 | 89 | 77 | 82 | 77 |
ACR-N [dB] | 102 | 102 | 101 | 98 | 89 | 84 | 80 | 77 | 74 | 64 | 56 |
PS-ACR-N [dB] | 99 | 99 | 99 | 95 | 86 | 81 | 77 | 74 | 71 | 61 | 53 |
ACR-F [dB] | 100 | 100 | 100 | 95 | 92 | 89 | 87 | 80 | 78 | 72 | 70 |
PS-ACR-F [dB] | 97 | 97 | 97 | 92 | 89 | 86 | 84 | 77 | 75 | 69 | 67 |
Return loss [dB] | 28 | 30 | 30 | 30 | 28 | 26 | 25 | 24 | 23 | 20 | 18 |
These performance data are typical measured values. |
Category: | Cat.8.2 |
Attenuazione di accoppiamento: | 75 dB |
Ritardo Skew: | 10 ns/100 m |
Impedenza a 100 MHz, ±5Ω: | 100 Ω |
Loop resistance at 20°C: | < 135 Ω/km |
Near end unbalance attenuation LCL at 1-600 MHz: | 20 dB |
NVP %: | 75 |
operating capacity: | 44 pF/m |
Transfer impedance 1/10/30 MHz: | < 8/10/40 mΩ/m |
Proprietà meccaniche
Curvatura minima durante l'installazione: | 64 mm |
Minimum bending radius permanently installed: | 32 mm |
Resistenza alla trazione (4P): | 110 N |
Resistenza minima allo schiacciamento / 10cm: | 1,000 N |
Minimum number of impacts: | 3 |
Installation temperature: | 0 °C - +50 °C |
Operating temperature: | -20 °C - +60 °C |
Reaction to fire (Euroclass)
EN 13501-6: DcaColore del cavo
white-blue/bluewhite-orange/orangewhite-green/greenwhite-brown/brown(with longitudinal stripes)in accordance with IEC 60189 and IEC 60708Impronta
DATWYLER «cable type» «additional text» «batch number» «meter marks»Zero alogeni, no gas corrosivi
IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2Propagazione delle fiamme
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2Diffusione delle fiamme
IEC 60332-3-24, EN 60332-3-24Densità del fumo
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2PoE
IEEE 802.3atEMC
shieldedClasse di segregazione
dCat./Class
Cat.8.2 (IEC 46C/1001/CD, draft, for channel length of 30 m)Documentation