CU 7702 4P / 2x4P F8

Data cable, S/FTP, Category 7A, AWG22, Euroclass B2ca

1 Inner conductor: AWG22 Bare copper wire
2 PE insulated conductor: 1.5 mm ∅
3 Screen (pair): Alu PETP foil  
4 Overall screen: Tinned braided copper 
5 Outer sheath: FRNC/LSOH orange RAL 2003

Description

Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, IEC 61156-7, EN 50173-1 and prEN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Easy identification of wires thanks to longitudinal colour markings.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018.
Due to the increased wire section eminently suited for Power over Ethernet (PoE) / PoE+.
Category   5e66A7CATV7A 
Frequency [MHz]141010025050060086210001500
Attenuation [dB/100m]1.73.45.316.9274042535669
NEXT [dB]1031031031031039896929085
PS NEXT [dB]1001001001001009593898782
ACR-N [dB]1011009886765854393421
PS-ACR-N [dB]98979583735551363118
ACR-F [dB]10910710593837065575443
PS-ACR-F [dB]10610410290806762545140
Return loss [dB]26303333282625242319
These performance data are typical measured values.
Category:Cat.7A
Attenuazione di accoppiamento:85 dB
Ritardo Skew:15 ns/100 m
Impedenza a 100 MHz, ±5Ω:100 Ω
Loop resistance at 20°C:< 116 Ω/km
Near end unbalance attenuation LCL at 1-600 MHz:40 dB
NVP %:76
operating capacity:43 pF/m
Transfer impedance 1/10/30 MHz:< 5/5/8 mΩ/m
Curvatura minima durante l'installazione:64 mm
Minimum bending radius permanently installed:32 mm
Resistenza alla trazione (4P):120 N
Resistenza alla trazione (2x4P):240 N
Resistenza minima allo schiacciamento / 10cm:1,000 N
Minimum number of impacts:10
Installation temperature:0 °C - +50 °C
Operating temperature:-20 °C - +60 °C

Reaction to fire (Euroclass)

EN 13501-6: B2ca

Colore del cavo

white-blue/bluewhite-orange/orangewhite-green/greenwhite-brown/brown(with longitudinal stripes)in accordance with IEC 60189 and IEC 60708

Impronta

DATWYLER «cable type» «additional text» «batch number» «meter marks»

Zero alogeni, no gas corrosivi

IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA

Propagazione delle fiamme

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1

Diffusione delle fiamme

IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Densità del fumo

IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

PoE

IEEE 802.3bt

EMC

shielded

Classe di segregazione

d

Cat./Class

Cat 7A / Class FA - limit values as specified by IEC 61156-5 and EN 50288-9-1 guaranteed

Documentation

ENDENLFRCNESIT
Product Datasheet
Tender text
GHMT PVP Certificates
GHMT PM/Channel Certificates
Transmission Parameter

Versions

Article No.DoPProdottoReaction to fire (Euroclass)Dimensioni n x p x [mm (AWG)]GuainaColore della guainaGuaina Ø [mm]Peso [kg/km]Tasso di Cu [kg/km]Carico di fuoco [MJ/m]Carico di fuoco [kWh/m]PU
17739002BLCU 7702 2x4PB2ca-s1b,d1,a12 x (4 x 2 x 0.62 (AWG22))FRNC/LSZHarancia7.6 x 16.212569.81.29 MJ/m0.36500 m tamburo
17740000BKCU 7702 4PB2ca-s1a,d1,a14 x 2 x 0.62 (AWG22)FRNC/LSZHarancia7.66234.90.64 MJ/m0.181000 m tamburo

Prodotti correlati

KS-TC Plus Cat.6A (IEC) tool-less, compact

RJ45 module, shielded, Category 6A (IEC)

Patch panel KS 48x-a, angled

for 48 modules with Keystone fitting