FM – Low Fire Hazard – supported
Mid rise - travelling height maximum 150m

Drawing according to article number 185124 - Type 8696-F




Description
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Core flexible: | class 5 |
Core insulation: | low fire hazard |
Data elements: | Please find our detailed interactive product overview here. |
Supporting members: | HTF = High tensile fibre |
Outer sheath: | low fire hazard |
Rated voltage Uo/U: | according to table |
Propriétés mécaniques
Free suspension length: | maximum 80 m |
Travelling height: | maximum 150 m |
Running speed: | maximum 6.3 m/s |
Acceleration: | < 1.2 m/s2 |
Operating temperature: | -15 to +70 °C |
Recommended loop diameter: | according to table, tolerance -50/+100 mm |
Code couleurs
Core: | black, white numbered, |
G = with green-yellow core(s) | |
Pair/quad: | various colours or black with white numbers |
Coax: | black |
Couleur de la gaine
blackNormes
EN 50214
Documentation
Versions
N° d'article | Membres de soutien | Dimensions globales [mm x mm] | Aire de section transversale [n x mm²] | Dispositif de suspension | Des éléments de données | Boucle [mm] | Poids [kg/100m] | Produit | Poids Cu [kg/km] | Tension nominale [V] | Normes |
---|---|---|---|---|---|---|---|---|---|---|---|
185127 | HTF | 48.4 x 6.0 | 12 G 1.00 + 1 x CX 75 Ω | LZ 1006 |
HF-2123-F | 400 | 48.4 | 8622-F | 139 | 300/500
| EN 50214 |
185124 | HTF | 48.4 x 6.0 | 12 G 1.00 + 1 x 4 x 0.34 | LZ 1006 | 8607-F | 400 | 49.9 | 8696-F | 142 | 300/500 300/300 | EN 50214 |
191094 | HTF | 79.0 x 5.7 | 3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.50 | LZ 1009 |
6651-F
| 400 | 81.8 | 8872-F | 232 | 450/750 300/500 300/300 | EN 50214 |
Produits apparentés
FL – Low Fire Hazard – unsupported
Low rise - travelling height maximum 80m
FH – Low Fire Hazard – supported
High rise - travelling height maximum 400m