EN-60KDS
High-end Network insulator
Surge protection and galvanic isolation
in one compact Keystone module

Description
Can be used in any Keystone-compatible wall outlet panel.
When retrofitting existing installations its rear connecting cable acts as a simple extension.
Meets the performance requirements of TIA 568 Cat.5e and ISO 11801 Class D in the Permanent Link and is thus designed for transmissions of up to 1 gigabit per second.
In medical technology, recording studios, measuring and monitoring technology and in the potentialfree connection of remote computer systems.
Galvanic isolation of any device connected to a copper-based Ethernet network (wires and screen).
Suppresses potential equalisation currents and protects medical and non-medical equipment and systems from the consequences of dangerous network voltage surges which can be caused by switching operations, moisture, electrostatic discharge, differences in potential or lightning strike.
Attenuates low-frequency signal components so well that it effectively prevents ripple pickup in connected devices.
Galvanic isolation of any device connected to a copper-based Ethernet network (wires and screen).
Suppresses potential equalisation currents and protects medical and non-medical equipment and systems from the consequences of dangerous network voltage surges which can be caused by switching operations, moisture, electrostatic discharge, differences in potential or lightning strike.
Attenuates low-frequency signal components so well that it effectively prevents ripple pickup in connected devices.
Electric strength: | 6000 VAC at 50 Hz (1 min.), 8500 VDC |
Max. applied voltage (permanent): | 400 VAC at 50/60 Hz |
Insertion Loss: | < 1dB (1 MHz < f < 100 MHz) |
Supported network protocols: | IEEE802.3 10BaseT (Cl.14), 100BaseTx (Cl.25), 1000BaseT (Cl.40) |
Labellings: | CE, UL (E249126), RoHS compliant, lead-free |
Mechanical properties
operating temperature: up to
Dimensions
Length of connecting cable: | 20 cm = standard on stock, other lengths on request (from 3 cm up to 10 m) |
Dimensions (housing w/o cable): | H x W x L = 23.5 x 17.3 x 39.9 mm |
Note
Datwyler is a distribution partner of EMO Systems GmbH
Standards
IEC 60601- 1:1988 A1:1991 and A2: 1995 (2nd Edition); IEC 60601-1-1:2000; IEC 60601- 1: 2005 (3rd Edition); IEC 60601-1-2:2007; UL 60601; IEC 61000-4-2 (ESD; 15kV Air / 8kV Contact); IEC 61000-4-4 (EFT; 40A, 5/50ns) and IEC 61000-4-5 (Lightning; 12A 8/20 μs)Documentation
Versions
Article No. | Product | Description | PU |
---|---|---|---|
417906 | EN-60KDS | High-end network isolator EN-60KDS, length = ? cm | 1 pc. |
417916 | EN-60KDS | High-end network isolator EN-60KDS, length = 20 cm | 1 pc. |
Related products
RJ45 patch cords Cat.6A IEC
500 MHz, shielded, wiring 1:1
RJ45 patch cords Cat.6
250 MHz, unshielded, wiring 1:1
RJ45 patch cords Cat.6 AWG28
250 MHz, unshielded, wiring 1:1