CU 6052 4P / 2x4P F8
Data cable, F/FTP, Category 6, AWG23, Euroclass Cca

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Alu PETP foil
5 Drain wire: Tinned copper wire
6 Outer sheath: FRNC/LSOH Orange RAL 2003












Description
Good shielding effect due to individually screened pairs and overall foil screen.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.

Category | 5e | 6 | ||||
Frequency [MHz] | 1 | 4 | 10 | 100 | 250 | 300 |
Attenuation [dB/100m] | 2.1 | 3.8 | 5.9 | 19.8 | 30 | 32 |
NEXT [dB] | 93 | 93 | 93 | 93 | 83 | 80 |
PS NEXT [dB] | 90 | 90 | 90 | 90 | 80 | 79 |
ACR-N [dB] | 91 | 89 | 87 | 73 | 53 | 48 |
PS-ACR-N [dB] | 88 | 86 | 84 | 70 | 50 | 45 |
ACR-F [dB] | 96 | 96 | 96 | 74 | 56 | 49 |
PS-ACR-F [dB] | 93 | 93 | 93 | 71 | 53 | 46 |
Return loss [dB] | 26 | 28 | 30 | 30 | 27 | 26 |
These performance data are typical measured values. |
Category: | Cat.6 |
Coupling attenuation: | 65 dB |
Delay Skew: | 5 ns/100 m |
Impedance at 100 MHz, ±5Ω: | 100 Ω |
Loop resistance at 20°C: | < 150 Ω/km |
Near end unbalance attenuation LCL at 1-600 MHz: | 40 dB |
NVP %: | 79 |
operating capacity: | 42 pF/m |
Transfer impedance 1/10/30 MHz: | < 50/100/200 mΩ/m |
Mechanical properties
Minimum bending radius during installation: | 56 mm |
Minimum bending radius permanently installed: | 28 mm |
Tensile strength (4P): | 95 N |
Tensile strength (2x4P): | 190 N |
Minimal crush resistance / 10cm: | 1,000 N |
Minimum number of impacts: | 10 |
Installation temperature: | 0 °C - +50 °C |
Operating temperature: | -20 °C - +60 °C |
Reaction to fire (Euroclass)
EN 13501-6: CcaWire colour
white/bluewhite/orangewhite/greenwhite/brownin accordance with IEC 60189 and IEC 60708Imprint
DATWYLER «cable type» «additional text» «batch number» «meter marks»Zero halogen, no corrosive gases
IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SAFlame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1Flame spread
IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SDPoE
IEEE 802.3afEMC
shieldedSegregation class
cCat./Class
Cat 6 / Class E - limit values as specified by IEC 61156-5v and EN 50288-5-1 guaranteedDocumentation