CU 502 4P Eca
Data cable, U/UTP, Category 5e, AWG24, Euroclass Eca

1 Inner conductor: AWG24 Bare copper wire
2 PE insulated conductor: 0,94 mm ∅ PE
3 Outer sheath: FR/PVC grey RAL 7037, FRNC/LS0H orange RAL 2003









Description
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.

Category | 5e | ||||
Frequency [MHz] | 1 | 4 | 10 | 100 | 125 |
Attenuation [dB/100m] | 1.9 | 3.7 | 6.0 | 19.8 | 22.3 |
NEXT [dB] | 71 | 61 | 55 | 40 | 39 |
PS NEXT [dB] | 68 | 58 | 52 | 37 | 36 |
ACR-N [dB] | 69 | 57 | 49 | 20 | 17 |
PS-ACR-N [dB] | 66 | 54 | 46 | 17 | 14 |
ACR-F [dB] | 76 | 68 | 57 | 34 | 32 |
PS-ACR-F [dB] | 73 | 65 | 54 | 31 | 29 |
Return loss [dB] | 26 | 29 | 30 | 27 | 26 |
These performance data are typical measured values. |
Category: | Cat.5e |
Coupling attenuation: | |
Delay Skew: | |
Impedance at 100 MHz, ±5Ω: | 100 Ω |
Loop resistance at 20°C: | < 170 Ω/km |
Near end unbalance attenuation LCL at 1-600 MHz: | |
NVP %: | 69 |
operating capacity: | 50 pF/m |
Transfer impedance 1/10/30 MHz: |
Mechanical properties
Minimum bending radius during installation: | 44 mm |
Minimum bending radius permanently installed: | 22 mm |
Tensile strength (4P): | 87 N |
Minimal crush resistance / 10cm: | |
Minimum number of impacts: | |
Installation temperature: | 0 °C - +50 °C |
Operating temperature: | -20 °C - +60 °C |
Reaction to fire (Euroclass)
EN 13501-6: EcaWire colour
white - blue/bluewhite - orange/orangewhite - green/greenwhite - brown/brownin accordance with IEC 60189 and IEC 60708 (ring marked)Imprint
DATWYLER «cable type» «additional text» «batch number» «meter marks»Zero halogen, no corrosive gases
IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SAFlame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD - applies to FRNC/LS0HPoE
IEEE 802.3afSegregation class
bCat./Class
Cat 5e / Class D - limit values as specified by IEC 61156-5 and EN 50288-3-1 guaranteedDocumentation
Versions
Article No. | Product | Reaction to fire (Euroclass) | Dimensions n x p x [mm (AWG)] | Sheath | Sheath colour | Sheath Ø [mm] | Weight [kg/km] | Cu rate [kg/km] | Fire load [MJ/m] | Fire load [kWh/m] | PU |
---|---|---|---|---|---|---|---|---|---|---|---|
24013200EP | CU 502 4P | Eca | 4 x 2 x 0.51 (AWG24) | FR/PVC | grey | 5.5 | 49 | 18.1 | 0.49 MJ/m | 0.14 | 305 m PullQuick box |
24013500EP | CU 502 4P | Eca | 4 x 2 x 0.51 (AWG24) | FRNC/LSZH | orange | 5.5 | 30 | 18.1 | 0.43 MJ/m | 0.12 | 305 m PullQuick box |
Related products
CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass Dca
CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass Cca
CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass B2ca