CU 502 4P Eca

Data cable, U/UTP, Category 5e, AWG24, Euroclass Eca

1 Inner conductor: AWG24 Bare copper wire
2 PE insulated conductor: 0,94 mm ∅ PE
3 Outer sheath: FR/PVC grey RAL 7037, FRNC/LS0H orange RAL 2003

Description

Electrically and mechanically advanced quality Cat 5e data cable - fulfils the requirements of ISO/IEC 11801-1, IEC 61156-5, EN 50173-1 and EN 50288-3-1.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class D applications (100 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
Category   5e 
Frequency [MHz]1410100125
Attenuation [dB/100m]1.93.76.019.822.3
NEXT [dB]7161554039
PS NEXT [dB]6858523736
ACR-N [dB]6957492017
PS-ACR-N [dB]6654461714
ACR-F [dB]7668573432
PS-ACR-F [dB]7365543129
Return loss [dB]2629302726
These performance data are typical measured values.
Category:Cat.5e
Coupling attenuation:
Delay Skew:
Impedance at 100 MHz, ±5Ω:100 Ω
Loop resistance at 20°C:< 170 Ω/km
Near end unbalance attenuation LCL at 1-600 MHz:
NVP %:69
operating capacity:50 pF/m
Transfer impedance 1/10/30 MHz:
Minimum bending radius during installation:44 mm
Minimum bending radius permanently installed:22 mm
Tensile strength (4P):87 N
Minimal crush resistance / 10cm:
Minimum number of impacts:
Installation temperature:0 °C - +50 °C
Operating temperature:-20 °C - +60 °C

Reaction to fire (Euroclass)

EN 13501-6: Eca

Wire colour

white - blue/bluewhite - orange/orangewhite - green/greenwhite - brown/brownin accordance with IEC 60189 and IEC 60708 (ring marked)

Imprint

DATWYLER «cable type» «additional text» «batch number» «meter marks»

Zero halogen, no corrosive gases

IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA

Flame propagation

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1

Smoke density

IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD - applies to FRNC/LS0H

PoE

IEEE 802.3af

Segregation class

b

Cat./Class

Cat 5e / Class D - limit values as specified by IEC 61156-5 and EN 50288-3-1 guaranteed

Documentation

ENDENLFRCNESIT
Product Datasheet
Tender text

Versions

Article No.ProductReaction to fire (Euroclass)Dimensions n x p x [mm (AWG)]SheathSheath colourSheath Ø [mm]Weight [kg/km]Cu rate [kg/km]Fire load [MJ/m]Fire load [kWh/m]PU
24013200EPCU 502 4PEca4 x 2 x 0.51 (AWG24)FR/PVCgrey5.54918.10.49 MJ/m0.14305 m PullQuick box
24013500EPCU 502 4PEca4 x 2 x 0.51 (AWG24)FRNC/LSZHorange5.53018.10.43 MJ/m0.12305 m PullQuick box