CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass Cca

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.6 mm ∅
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSOH Orange RAL 2003












Description
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compact cable design.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
High-end data cable for data centres.
Developed particularly for 40 GBase-T transmission with maximum channel length of 30 metres in End of Row or Top of Rack (EoR / ToR) applications in data centres.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to 2000 MHz.
Applicable for Power over Ethernet (PoE / PoE+).
Developed particularly for 40 GBase-T transmission with maximum channel length of 30 metres in End of Row or Top of Rack (EoR / ToR) applications in data centres.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to 2000 MHz.
Applicable for Power over Ethernet (PoE / PoE+).

Category | 5e | 6 | 6A | 7 | CATV | 7A | 8.2 | ||||
Frequency [MHz] | 1 | 4 | 10 | 100 | 250 | 500 | 600 | 862 | 1000 | 1600 | 2000 |
Attenuation [dB/30m] | 0.54 | 0.95 | 1.5 | 5.0 | 8.0 | 11.3 | 12.5 | 15.6 | 16.3 | 21.0 | 23.5 |
NEXT [dB] | 103 | 103 | 103 | 103 | 97 | 95 | 94 | 92 | 90 | 85 | 80 |
PS NEXT [dB] | 100 | 100 | 100 | 100 | 94 | 92 | 91 | 89 | 77 | 82 | 77 |
ACR-N [dB] | 102 | 102 | 101 | 98 | 89 | 84 | 80 | 77 | 74 | 64 | 56 |
PS-ACR-N [dB] | 99 | 99 | 99 | 95 | 86 | 81 | 77 | 74 | 71 | 61 | 53 |
ACR-F [dB] | 100 | 100 | 100 | 95 | 92 | 89 | 87 | 80 | 78 | 72 | 70 |
PS-ACR-F [dB] | 97 | 97 | 97 | 92 | 89 | 86 | 84 | 77 | 75 | 69 | 67 |
Return loss [dB] | 28 | 30 | 30 | 30 | 28 | 26 | 25 | 24 | 23 | 20 | 18 |
These performance data are typical measured values. |
Category: | Cat.8.2 |
Coupling attenuation: | 75 dB |
Delay Skew: | 10 ns/100 m |
Impedance at 100 MHz, ±5Ω: | 100 Ω |
Loop resistance at 20°C: | < 135 Ω/km |
Near end unbalance attenuation LCL at 1-600 MHz: | 20 dB |
NVP %: | 75 |
operating capacity: | 44 pF/m |
Transfer impedance 1/10/30 MHz: | < 8/10/40 mΩ/m |
Mechanical properties
Minimum bending radius during installation: | 64 mm |
Minimum bending radius permanently installed: | 32 mm |
Tensile strength (4P): | 110 N |
Minimal crush resistance / 10cm: | 1,000 N |
Minimum number of impacts: | 3 |
Installation temperature: | 0 °C - +50 °C |
Operating temperature: | -20 °C - +60 °C |
Reaction to fire (Euroclass)
EN 13501-6: CcaWire colour
white-blue/bluewhite-orange/orangewhite-green/greenwhite-brown/brown(with longitudinal stripes)in accordance with IEC 60189 and IEC 60708Imprint
DATWYLER «cable type» «additional text» «batch number» «meter marks»Zero halogen, no corrosive gases
IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2Flame propagation
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2Flame spread
IEC 60332-3-24, EN 60332-3-24Smoke density
IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2PoE
IEEE 802.3atEMC
shieldedSegregation class
dCat./Class
Cat.8.2 (IEC 46C/1001/CD, draft, for channel length of 30 m)Documentation
Versions
Related products
CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass Dca
CU 8203 4P
Data cable, S/FTP, Category 8.2, AWG23, Euroclass B2ca