FL – Low Fire Hazard – unsupported

Low rise - travelling height maximum 80m

Drawing according to article number 191113 - Type 8582-F

Beschreibung

Elevator suspension cable for indoor and panoramic elevators.
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Core flexible:class 5
Core insulation:low fire hazard
Data elements:

Please find our detailed interactive product overview here.

Supporting members:none
Outer sheath:low fire hazard
Rated voltage Uo/U:according to table
Free suspension length:maximum 45 m
Travelling height:maximum 80 m
Running speed:maximum 4 m/s
Acceleration:< 0.8 m/s2
Operating temperature:-15 to +70 °C
Recommended loop diameter:according to table, tolerance -50/+100 mm
Core:black, white numbered,
G = with green-yellow core(s)
Pair/quad:various colours or black with white numbers
Coax:black

Mantelfarbe

black

Anwendbare Normen

EN 50214

Dokumentation

ENDENLFRCNESIT
Produktdatenblatt

Versionen

Artikelnr.ProduktCu-Zahl [kg/km]Nennspan- nung [V]NormenSchleife [mm]AufhängevorrichtungUnterstützende MitgliederGewicht [kg/100m]DatenelementeOverall dimensions [mm x mm]Querschnittsfläche
191110 8511-F 87

300/500

EN 50214 300 LZ 1006 none 25.9 34.3 x 4.4

12 G 0.75

185125 8511-F 130

300/500

EN 50214 300 LZ 1006 none 38.2 49.4 x 4.4

18 G 0.75

191112 8511-F 173

300/500

EN 50214 300 LZ 1009 none 51.1 66.7 x 4.4

24 G 0.75

191111 8636-F 123

300/500

300/300

EN 50214 400 LZ 1006 none 42

6651-F

47.4 x 5.4

12 G 0.75

+ 3 x 2 x 0.50

182205 8827-F 244

450/750

300/500

300/300

EN 50214 400 LZ 1009 none 73.5

 

 

7345-F

72.3 x 5.8

3 G 2.50

+ 14 x 1.00

+ 4 x 2 x 0.34

191113 8582-F 306

300/500

300/300

EN 50214 400 LZ 1010 none 95.8

 

6651-F

HF-2123-F

87.3 x 6.5

24 G 1.00

+3 x 2 x 0.75

+ 1 x CX 75 Ω

190491 8582-F 149

450/750

300/300

EN 50214 450 LZ 1006 none 52.4

 

6651-F

HF-2123-F

47.8 x 7.1

2 x 1.50

+ 8 x 2 x 0.50

+ 1 x CX 75 Ω

Verwandte Produkte

FM – Low Fire Hazard – supported

Mid rise - travelling height maximum 150m

FH – Low Fire Hazard – supported

High rise - travelling height maximum 400m